Test Recording Sheet:
Report by: SIRDO Canada Inc. sirdocan@netcom.ca, phone 519-631-6035 |
||||
|
|
* Before |
After |
After |
After |
|
Cell |
Installation |
5 Cycles |
10 Cycles |
15 Cycles |
|
(Date) |
Nov. 21/98 |
Nov. 27/98 |
Dec. 7/98 |
Dec. 8/98 |
|
1 |
1.190 |
1.300 |
1.280 |
1.290 |
|
2 |
1.200 |
1.300 |
1.280 |
1.290 |
|
3 |
1.225 |
1.300 |
1.300 |
1.300 |
|
4 |
1.225 |
1.300 |
1.300 |
1.300 |
|
5 |
1.225 |
1.300 |
1.300 |
1.300 |
|
6 |
1.200 |
1.300 |
1.280 |
1.290 |
|
||||
|
|
* Before |
After |
After |
|
|
Cell |
Installation |
|
|
|
|
(Date) |
Jan 4-0930 hrs. |
Jan 4-2200 hrs. |
Jan 5-1415 hrs. |
|
|
1 |
1.250 |
1.270 |
1.280 |
|
|
2 |
1.275 |
1.300 |
1.300 |
|
|
3 |
1.260 |
1.290 |
1.300 |
|
|
4 |
1.275 |
1.300 |
1.300 |
|
|
5 |
1.250 |
1.275 |
1.280 |
|
|
6 |
1.240 |
1.275 |
1.280 |
|
|
The specific gravity was taken & also tested with a Volt Meter and a Midtronics model 450 digital battery analyzer |
||||
| Results: | ||||
|
Jan 4- 0930 hrs. - the readings were taken before the battery was charged with the CP-12 Charge Partner. |
||||
|
|
||||
|
Volt Meter - 12.72 volts Midtronics - Cold Cranking Amps
(CCA)- 469, 12.59 volts - replace battery. |
||||
|
Jan 4-2200 hrs. - battery trickle charged with the CP-12 Charge Partner for 12.5 hrs |
||||
|
Volt Meter - 14.23 volts- Midtronics - CCA - 541, 14.02 volts - replace battery |
||||
|
Jan 5-1415 hrs. - battery trickle charged with the CP-12 Charge Partner for 29.75 hrs. |
||||
|
Volt Meter - 14.47 volts Midtronics - CCA - 591, 14.22 volts - good battery |
||||